RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Nordsyn study on air-to-water heat pumps in humid Nordic climate
(RISE Research Institutes of Sweden AB)
(RISE Research Institutes of Sweden AB)
Ansvarlig organisasjon
2019 (engelsk)Bok (Annet vitenskapelig)
Abstract [en]

The study presented in this report has been performed for Nordsyn sponsored by the Nordic Council of Ministers. The aim of this study was to analyse if the information given on the energy labels of air-to-water heat pumps give consumers in Nordic countries sufficient information on energy performance. When comparing results from field measurements to declared values, it shows the declared values are usually better than the field data, especially in countries with humid climate. There could be several reasons for this deviation as non-optimal installations, bypass of control systems, old field data etc. The suspicion that the deviation is due to that the standard tests do not take humidity sufficiently into account could not be proved nor fully dismissed. Recommendations are given on how this could be further investigated, including field measurements in Nordic countries.

sted, utgiver, år, opplag, sider
Copenhagen: Nordisk Ministerråd, 2019. , s. 111
Serie
TemaNord, ISSN 0908-6692 ; 2019:502
HSV kategori
Forskningsprogram
Nordiska lösningar; Miljö och klimat; Hållbar konsumtion och produktion; Nordliga dimensionen; Energi; Polissamarbete; Ekonomi
Identifikatorer
URN: urn:nbn:se:norden:org:diva-5590DOI: 10.6027/TN2019-502ISBN: 978-92-893-5971-9 (tryckt)ISBN: 978-92-893-5972-6 (digital)ISBN: 978-92-893-5973-3 (digital)OAI: oai:DiVA.org:norden-5590DiVA, id: diva2:1312951
Tilgjengelig fra: 2019-05-03 Laget: 2019-05-01 Sist oppdatert: 2019-08-20

Open Access i DiVA

Download free PDF(6182 kB)139 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 6182 kBChecksum SHA-512
a0722600c38d806f0d15e5d035ad97388618614e752efa3417c1e047e1416d5a07a8f680fee31c1668866b6a3bb402948450490e8aa7add125392c76c92528ca
Type fulltextMimetype application/pdf
Download ePub(10974 kB)10 nedlastinger
Filinformasjon
Fil FULLTEXT02.epubFilstørrelse 10974 kBChecksum SHA-512
ac23a18215299bc1ad4d20950b1ca399e08b27d9577b572f63b28abc9ee71563691fb8984a17ea1ba9071ab31683681680c4d368c871e11e753a5ccf08264230
Type fulltextMimetype application/epub+zip

Andre lenker

Forlagets fulltekstNordsyn study on air-to-air heat pumps in humid Nordic climate

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 149 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 359 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf